DETERMINATION OF ATORVASTATIN CALCIUM IN PHARMACEUTICAL FORMULATIONS BY REVERSE PHASE-HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

Authors

  • Manoj S. Charde Government College of Pharmacy, Kathora Naka, Amrawati-444604 Maharashtra
  • A. Gupta NRI Institute of Pharmaceutical Science, Bhopal-462010
  • R. D. Chakole Department of Pharmacy, Government Polytechnic, Amravati

DOI:

https://doi.org/10.7439/ijapa.v1i2.6

Abstract

A simple, sensitive and reproducible reverse-phase high performance liquid chromatographic (RP-HPLC) method has been developed for the quantitative estimation of Atorvastatin calcium in the pharmaceutical formulations. Chromatographic separation was achieved on a 250 × 4.6 mm, 5μ, Waters symmetry column. The flow rate was 1ml/min and eluent was monitored by absorbance at 246 nm using a mixture of Methanol and Acetonitrile (pH 3.0

Downloads

Download data is not yet available.

Downloads

Published

2012-01-01

Issue

Section

Research Articles

How to Cite

1.